Newton’s 4th application notes: we brengen ze onder de aandacht

 

“Only my application brings me success”

Isaac Newton heeft ooit eens bovenstaande uitspraak gedaan voor wat betreft zijn wet van behoud van energie: Newton’s 3rd Law.

Hoe mooi is het dan niet om deze uitspraak te gebruiken om de application notes van onze leverancier Newton’s 4th bij u onder de aandacht te brengen. Unieke voorbeelden van applicaties waar de Newton’s 4th Power analyzers en Frequentie Response Analyzers worden toegepast.

De Newton’s 4th application notes

DFT or FFT? A Comparison of Fourier Transform Techniques. The Discrete Fourier Transform(DFT) is a demanding algorithm

APP030 investigates the benefits of the DFT and why N4L do not utilise the FFT for harmonic analysis. APP030 – DFT or FFT – A Comparison of Fourier Transform Techniques (PDF, 372KB)  

Capacitor Analysis with High DC Bias Voltage

In this application note, a PSM1700 Frequency Response analyzer, LPA400 Power amplifier and a HF01A Current shunt are used to analyze the capacitance of a 1uF capacitor whilst subjected to varying DC bias voltages. APP029 – Capacitor Impedance Measurements with High DC Voltage Biasing (PDF, 179KB)    

N4L Harmonics and Flicker Compliance Verification of PPA55xx to IEC61000-3-2, IEC61000-3-3, IEC61000-3-11, IEC61000-3-12 

This application note discusses measurements made with PPA5500 family of precision power analyzers from Newtons4th Ltd in order to verify the performance of the analyzer in a test system fully compliant to the relevant standards. APP028 – N4L Harmonics and Flicker Compliance Verification of PPA55xx to IEC61000-3-2, 3-3, 3-11 & 3-12 (PDF, 179KB)

IEC61000-3-3 2013 Electromagnetic Compatability – A guide to Flicker Measurement

N4L provides ISO17025 UKAS Accredited Flickermeters, and this application note discusses what flicker is and the field of flicker measurement. APP026 – IEC61000-3-3 2013 Electromagnetic Compatability – A Technical Guide to Flicker Measurement (PDF, 800KB)

PWM Motor Drive Ramp Testing with the PPA45/5500 Power Analyzers

This application note discusses the setup and analysis of PWM Inverter Motor Drives, specifically when rapid fundamental frequency and load change is likely. APP025 –PWM Motor Drive Ramp Testing with the PPA45_5500 Power Analyzers (PDF, 153KB)  

Sweep Frequency Response Analysis of Power Transformers – Typical Test Sequences (IEC60076-18)

In this application note, we discuss the mathematics behind harmonics analysis. APP024 –Sweep Frequency Response Analysis of Power Transformers – Typical Test Sequences IEC60076-18 (PDF,164KB)  

Harmonic Analysis in Power Applications

In this application note, we discuss the mathematics behind harmonics analysis. APP023 – Harmonic Analysis in Power Applications (PDF, 67.2KB)        

PSRR (Power Supply Rejection Ratio) Testing

Power Supply Rejection Ratio (PSRR) analysis presents the engineer with numerous measurement challenges, specifically the task of perturbation signal injection. This application note describes the approach to such a measurement utilizing the PSM3750 Frequency Response Analyser and an injection inductor. APP022 –PSRR – Power Supply Rejection Ratio Testing(PDF, 390KB)    

Master Slave Efficiency Testing

In this application note, we delve into the world of efficiency testing and take a look at the downfalls instruments using gapped measurement techniques suffer from. We describe the N4L approach to such testing and reasons why we offer more reliable and more accurate measurements than those possible with traditional techniques. APP021 –Master Slave Effieicency testing (PDF, 160KB)    

Amplifier Frequency Response  

This application note discusses frequency response analysis of a power amplifier including a detailed guide describing the set up of the PSM1735 frequency response analyzer. APP020 – Amplifier Frequency Response (PDF, 160KB)    

RMS and Peak range consideration in Precision Power Analyzers  

This application note discusses RMS and Peak range considerations when analyzing modern power electronic waveforms. We look at both approaches and discuss why N4L’s measurement techniques offer superior data capture. APP019 – RMS and Peak range considerations with Precision Power Analyzers (PDF, 175KB)    

Transformer Efficiency testing and Transformer Vector Theory

In this application note, we discuss the losses in a transformer, how these losses effect the power factor on the primary and how the nature of the load on the secondary effects the power factor on the primary. APP018 –Transformer Efficiency Testing and Transformer Vector Theory (PDF, 405KB    

PWM Motor Drives – Pulse Width Modulation Theory  

Pulse Width Modulation has become a common approach to motor control, this application note provides an introduction to the concept and discusses measurement considerations test and development engineers should consider when selecting test equipment. APP017 – PWM Motor Drives – Pulse Width Modulation Theory (PDF, 810KB)    

RFI Line Filter Testing – Frequency Response Analysis

RFI or Radio Frequency Interference present at the input of equipment connected to the power line is filtered out with a line filter in order to prevent the unwanted interference in the radio frequency band disrupting the correct operation of electronic equipment. This application note will take the engineer through testing RFI Line filters with the PSM1735 Frequency Response Analyser. APP016 –Testing RFI Line Filters – Frequency Response Analysis (PDF, 759KB)    

Standby Power Testing – IEC62301  

This application note describes the challenges associated with standby power testing to IEC62301, it describes how Newtons4th’s power analyzers make stable, accurate measurements in this field. We also describe how to use our testing software and illustrate how simple it is to use. APP015 – Standby Power Measurement – IEC62301 (PDF, 2,183KB)    

3 Phase 2 Wattmeter Explained – Power Analysis  

3 Phase 2 Wattmeter is a common configuration in use in the power measurement field, in this application note we explain the maths behind the measurements in order to understand how 2 wattmeters can measure power on 3 phases. Real Voltages and currents are used in order to make sense of the theory and we explore both balanced and unbalanced loads. APP014 – 3 Phase 2 Wattmeter Explained (PDF, 663KB)         

Efficiency Measurements of AC – DC Power supplies using the PPA1500 series Power Analyzers  

The PPA1500 series power analyzers (PPA1520 + PPA1530) have benefited from a firmware upgrade which has enabled the instrument to perform AC-DC power supply efficiency measurements. The PPA1500 series provides the engineer with an accurate, affordable and simple to set up the Power Analyzer, see our products section for more details. The PPA1500 series possess a high accuracy specification as a result of innovative analog and digital design techniques, these also offer the engineer high performance at a lower price. APP013 – AC – DC Efficiency Measurements with the PPA1520 (PDF, 255KB)    

Unique N4L Current Shunt Design – Field Cancellation  

Newtons4th Ltd have developed a unique current shunt that incorporates excellent field cancellation characteristics whilst maintaining low manufacturing costs. This application note details the theory behind the design of the shunt and the importance of low inductance characteristics of current shunts in power analysis. APP012 –Current Shunt Field Cancellation (PDF, 590KB)    

Testing communications transformers  

PSM units are well suited to testing transformers either manually or automatically (using a PC). Using DFT and true rms measurements over a wide frequency range, PSM units used in conjunction with our transfer testing accessories perform most commonly required transformer tests. Testing communications transformers(PDF, 66KB    

Testing loop stability  

PSM units are ideally suited to measuring the gain/phase response of a control loop by injecting a small disturbance and analysing the results. The PSM range use DFT analysis (Discrete Fourier Transform) to measure the relative gain and phase of the signal round the loop at the specific test frequency, rejecting any other frequency components present (such as noise or ripple). The test frequency can be swept automatically over the desired frequency range and the results viewed on the screen or printed out… Testing loop stability (PDF, 52KB)    

Using the PSM Series with LVDTs

LVDTs (Linear Variable Differential Transformer) consists of a transformer with one primary winding, two secondary windings and a moveable armature. With the primary energised at a suitable frequency, the magnitude and relative phase of the secondaries change as the armature is moved. This document describes how the PSM2200 QuanteQ may be used to analyse such a system. Testing LVDTs (PDF, 27KB)    

Testing FSK communications  

FSK (frequency shift keying) is a well-established technique for encoding binary data by transmitting one frequency for zero’ and a different frequency for ‘one’. It is commonly used in industrial monitoring and control systems where transmitters and receivers may be separated by long distances. In order to have confidence in the communications, it is important to verify the signal levels at the receivers to detect any degradation in performance, such as would be caused by increased cable resistance or poor connectors. Testing FSKs (PDF, 11KB)    

Measuring fluctuating signals

The PSM range are real-time analysis instruments that simultaneously acquire and process data, once the input conditions are valid. The default set up conditions for the PSM range is most suitable for measuring steady state, or slowly fluctuating signals – for rapidly fluctuating signals there are three areas where the response of the instrument can be improved using the menus or the communication commands: 1. Input ranging; 2. Filtering; 3. Frequency determination. Measuring fluctuating signals (PDF, 16KB)    

 

High voltage capacitance measurement  

Some high voltage devices have different characteristics at the lower voltages usually used to measure capacitance. The LPA400 can be used with the PSM2200 or PSM2201 to analyse devices at up to 800V pk-pk from dc to 100kHz and up to 80V pk-pk up to 1MHz. Measurements of capacitance, ac resistance, tan(θ), and even power can be made under controlled conditions that are representative of the real operating conditions for the device.High voltage capacitance measurement(PDF, 23KB)    

Measuring low THD

Amongst the many measurement modes of the PSM range there is a harmonic analyzer that can measure a single harmonic or can compute total harmonic distortion (THD) from a series of harmonics. The PSM range measures THD by simultaneous computing a DFT for each of the harmonics in the series up to the maximum number specified. Measuring low THD (PDF, 23KB)    

LCR measurements

The PSM range can be used to measure the characteristics of inductors, capacitors and resistors under precise operating conditions. The two inputs are both voltage inputs so some external shunt arrangement is needed. By using an external shunt, the shunt can be optimised for the conditions of the test. The Active LCR head and Impedance Analysis Interface available as an accessory from N4L include a number of different high frequency shunts that can beselected from the instrument front panel. Alternatively, the circuit arrangements shown here can be used. LCR measurements (PDF, 90KB)

Wat onze klanten zeggen

Arnold Memelink

Arnold Memelink

ABB

"De ABB Power Grids Jumet organisatie is een innovatieve ontwikkelings- en productiefaciliteit van ABB die actieve filters en batterij-energieopslagsystemen produceert ter ondersteuning van een stabiel netwerk. Om deze systemen te testen hebben we twee Cinergia GE/EL +120kVA eplus units aangeschaft die in staat zijn om netemulatie (AC + DC) te doen, die werken als een elektronische belasting (AC +DC) en die een batterij-emulator zijn. We hebben zeer goede ondersteuning van TTMS ervaren bij het verkrijgen van deze twee Cinergia-units. Dit omvatte het organiseren van een demonstratie op locatie en het leveren van leensystemen voorafgaand aan de levering van onze uiteindelijke systemen. Op deze manier konden we zo vroeg mogelijk beginnen met testen. TTMS organiseerde ook trainingen voor de operators van de oorspronkelijke fabrikant. Dankzij deze ondersteuning konden we de eerste batterij-energie-opslagsystemen al voor de volledige levering van de Cinergia-systemen introduceren."

Universiteit van Luxemburg

Sasan Rafii-Tabrizi

Universiteit van Luxemburg

"Bij de afdeling Energie en Milieu van de Faculteit Wetenschappen, Technologie en Geneeskunde (FSTM) van de Universiteit van Luxemburg hebben we verschillende onderzoeksprojecten op het gebied van groene energie die bijdragen aan de ontwikkeling van eco-steden. Als langdurige partner van onze research afdeling heeft TT&MS bewezen zelfs de meest complexe vragen op een professionele manier te kunnen beantwoorden. Ze hebben aangetoond dat ze altijd op de hoogte zijn van de nieuwste technologie en geen enkele moeite sparen om de toepassing en zelfs de situatie ter plaatse te bekijken. De uitwisseling van ideeën was altijd erg prettig en vond snel plaats. We kijken uit naar verdere jaren van vruchtbare samenwerking."

ONZE LEVERANCIERS

© Copyright 2024 - TTMS B.V. | Privacy Policy | Algemene Voorwaarden